Graphite-Polyurethane Composite Electrode Modified with Molecularly Imprinted Polymer for Determination of Diclofenac
AUTOR(ES)
Pereira, Abigail V; Cervini, Priscila; Rivera, Victor A. G; Cavalheiro, Éder T. G
FONTE
Journal of the Brazilian Chemical Society
DATA DE PUBLICAÇÃO
2022
RESUMO
A molecularly imprinted polymer (MIP) was prepared using the anti-inflammatory diclofenac (DCF) as a template. A non-imprinted polymer (NIP) was also prepared as a control. These MIP and NIP were characterized by scanning electron microscopy (SEM), transmission electron microscopy (TEM) and Brunauer-Emmett-Teller (BET), revealing a higher porosity in the first. Then both were used in the modification of graphite-polyurethane composites electrodes (GPUE). Differential pulse anodic stripping voltammetry was used for DCF determination at GPUE MIP DCF containing 2.5% (m/m) of the modifier in perchloric acid, pH = 2.0, after previously optimized conditions such as 300 s of accumulation time, +0.2 V accumulation potential (vs. SCE (saturated calomel electrode)), 50 mV pulse amplitude and 10 mV s-1 scan rate. A linear dynamic range from 0.010 to 0.20 μmol L-1 and a limit of detection (LOD) of 0.99 nmol L-1 were found, using GPUE 2.5 MIP DCF. DCF was determined in commercial pharmaceutical formulations and in synthetic urine samples, with recoveries between 101 and 102% (n = 3) and 101% (n = 3), respectively. The results agreed with the reference high-performance liquid chromatography (HPLC) within 95% confidence level, according to Student’s t-test. Interference from meclofenamic and mefenamic acids, which are structurally similar to DCF, was also evaluated. Interferences could not be totally avoided, but MIPs presented a considerable ability in discriminating the voltammetric response for DFC, despite the close structural similarity with the interferents.
Documentos Relacionados
- Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
- Determination of paracetamol at a graphite-polyurethane composite electrode as an amperometric flow detector
- Using of a graphite-polyurethane composite electrode modified with a Schiff base as a bio-inspired sensor in the dopamine determination
- Evaluation of a Graphite-Polyurethane Composite Electrode Modified with Copper Nanoparticles as an Amperometric Flow Detector in a Wall-Jet System for the Determination of Cysteine
- A New Electrochemical Platform Based on a Polyurethane Composite Electrode Modified with Magnetic Nanoparticles Coated with Molecularly Imprinted Polymer for the Determination of Estradiol Valerate in Different Matrices