Evaluation of the Directigen Group A Strep test kit.
AUTOR(ES)
Miller, J M
RESUMO
The Directigen Group A Strep test kit (Hynson, Wescott, and Dunning, Baltimore, Md.) was tested for its ability to detect group A streptococci directly from 147 throat swabs. The results were compared with results from conventional culture and Lancefield serological grouping tests. The data showed that 121 of 124 culture-negative throat specimens were also Directigen negative (98%) and that 21 of 23 culture-positive specimens were Directigen positive (91%). If specimens that provided less than 10 colonies per plate of beta-hemolytic streptococci were eliminated, all of the culture-positive specimens were Directigen positive. Positive or negative results were available within 65 to 70 min of testing. The Directigen method is relatively simple to perform and easy to interpret and provides accurate assessment of the presence or absence of group A streptococci in throat swabs, with little or no cross-reactivity with other beta-hemolytic groups.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=271455Documentos Relacionados
- Evaluation of the rapid Patho Dx Latex Strep Grouping Kit.
- Evaluation of the Directigen 1,2,3 Group A Strep Test for diagnosis of streptococcal pharyngitis.
- Evaluation of a new immunologic test kit for rapid detection of group A streptococci, the Abbott Testpack Strep A plus.
- Comparison of the Directigen 1-2-3 Group A Strep Test with culture for detection of group A beta-hemolytic streptococci.