Ten microbiological departments in Norway have participated in a multicenter evaluation of the following commercial tests for detection of Epstein-Barr virus (EBV)-specific and heterophile antibodies: CAPTIA Select viral capsid antigen (VCA)-M/G/EBNA (Centocor Inc.), Enzygnost anti-EBV/immunoglobulin M (IgM) and IgG (Dade Behring), Vironostika EBV VCA IgM/IgG/EBNA enzyme-linked immunosorbent assay (ELISA) (Organon Teknika), SEROFLUOR immunofluorescence assay and EBV Combi-Test (Institute Virion Ltd.), anti-EBV recombinant IgM- and IgG-early antigen/EBNA IgG ELISA (Biotest Diagnostics), EBV IgM/IgG/EBNA ELISA (Gull Laboratories), Paul-Bunnell-Davidsohn test (Sanofi Diagnostics Pasteur), Monosticon Dri-Dot (Organon Teknika), Avitex-IM (Omega Diagnostics Ltd.), Alexon Serascan infectious mononucleosis test (Alexon Biomedical Inc.), Clearview IM (Unipath Ltd.), and Cards±OS Mono (Pacific Biotech, Inc.). The test panel included sera from patients with primary EBV infection, immunocompromised patients with recent cytomegalovirus infection, healthy persons (blood donors), and EBV-seronegative persons. Among the tests for EBV-specific antibodies the sensitivity was good, with only small differences between the different assays. However, there was a greater variation in specificity, which varied between 100% (Enzygnost) and 86% (Biotest). Tests for detection of heterophile antibodies based on purified or selected antigen (Avitex, Alexon, Clearview IM, and Cards±OS Mono) were more sensitive than the Paul-Bunnell-Davidsohn and Monosticon tests.