Estudo comparativo de soluções ultra diluídas de LiCl: espectroscopia de impedância no intervalo de frequência entre 1kHz e 13MHz / Comparative studies of ultra-higt diluídas de LiCl: espectroscopy in the frequency range of 1KHz to 13MHz
AUTOR(ES)
Adriana Ramos de Miranda
DATA DE PUBLICAÇÃO
2008
RESUMO
The impedance spectroscopy technique was applied to the physical characterization of ultra high dilutions of lithiun cloride, in the range 1kHz to 13MHz. This characterization was obtained, mainly, by investigating the behavior of the imaginary part of the impedance of diluted and dinamizated solutions, for concentrations down to 10-30M. The experimental results were compared to the ones obtained for water, which have been submitted to exactly the same process of dilution and dinamization. Preliminary tests were carried out in order to identify the best experimental conditions to be used, mainly in respect to choosing the samplestemperature. In result, the best measuring protocol was observed to be the one in which the liquid samples were measured at room temperature, mantained practically constant by an air conditioning system. The experimental data related to the real and imaginary part of the impedance, for each frequency value, were modeled by adjusting the parameters of an equivalent electric circuit. The results of this analysis showed that the impedance values of the ultra high dilutions and of the water agree quite well with the modelling, when the circuit are composed by a resistance r in series with a RC circuit (in parallel). The resistence R, calculated through the modelling by the equivalent circuit, was the best parameter to characterize both the ultra high dilutions (concentration smaller than 10-6M) as well as the water. Clear differences were also observed when the ultra high dilutions of LiCl 15cH (corresponding to 15a centesimal dilution) were compared to the water. A non-monotonous behavior was obtained when solutions from 3 to 15cH (corresponding to the same lot of samples) were measured.
ASSUNTO(S)
ultra diluição hahremann water Água dynamization hahnemann dinamização espectroscopia de impedância ultra-high dilutions impedance spectroscopy
Documentos Relacionados
- LiCl treatment releases a nickase implicated in genetic transformation of Streptococcus pneumoniae.
- Interaction of ethidium bromide with DNA: effect of LiCl and ethylene glycol.
- Dielectric behavior of wild-type yeast and vacuole-deficient mutant over a frequency range of 10 kHz to 10 GHz.
- Comparative study of the effect of 100 Hz and 16 Hz pulse repetition frequency 1 MHz ultrasound rat fibula fracture treatment
- Estudo comparativo do efeito do ultra-som de 1 MHz com freqüência de repetição de pulso a 100 Hz e 16 Hz no tratamento de fratura de fíbula de rato