Erosion of inferior vena caval filter noted during robotic assisted laparoscopic partial nephrectomy
AUTOR(ES)
Hutchinson, Ryan C., Thiel, David D., Igel, Todd C.
FONTE
Int. braz j urol.
DATA DE PUBLICAÇÃO
2012-10
RESUMO
Inferior Vena Cava (IVC) filters are mechanical devices implanted to provide prophylaxis against pulmonary emboli in patients for whom standard anticoagulation is either inadequate or contraindicated. A 67-year-old female with a 10-year-old indwelling IVC filter underwent robotic assisted laparoscopic partial nephrectomy for a right upper pole renal mass. Renal hilum dissection was complicated by adhesions secondary to eroded IVC filter struts. IVC filter erosion is a well-described phoenomena in both the radiologic and surgical literature. As many as 25% of filters are noted to be radiographically eroded; however, the incidence of clinically significant erosion is much less. Given the placement of endovascularly delivered IVC filters in close proximity to many urologic operative fields, it is important for urologists to be aware of the potential of eroded devices when pursuing para-caval dissections.