Diurnal changes of the intraocular pressure of patients with angle-closure glaucoma.
AUTOR(ES)
Shapiro, A
RESUMO
The diurnal curves of 21 patients (40 eyes) with angle-closure glaucoma and of 21 normotensive subjects (42 eyes) were studied. The patients with angle-closure glaucoma had a V-shaped diurnal curve that was completely different from the diurnal curve of the normotensive subjects. Most of the eyes of the patients with angle-closure glaucoma had a diurnal change of the intraocular pressure of 8 mmHg or more, while in the normotensive subjects only 1 eye had a diurnal change as large as 8 mmHg.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=1043452Documentos Relacionados
- Aetiology of angle-closure glaucoma.
- Fellow eye in angle-closure glaucoma.
- Aetiology of the anatomical basis for primary angle-closure glaucoma. Biometrical comparisons between normal eyes and eyes with primary angle-closure glaucoma.
- Primary angle-closure glaucoma. Inheritance and environment.
- Ocular dimensions in the heredity of angle-closure glaucoma.