The present research aimed to study the parameters that affect the determination of estrogens in sewage upon the use of SPE and determination by using gas chromatography mass spectrometry (GC/MS). The study evaluated the stabilization pond technology with regard to estrogens removal. The results showed that the methodology was able to identify and quantify the estrogens E1, E2, E2-17A and EE2 in sewage. Moreover, the estrogens sometimes were not removed in the stabilization pond, showing that even the high hydraulic retention time (HRT) and high sunlight intensity were not enough to degrade these compounds completely during load peaks.