Degradação de poluentes emergentes por processos Fenton e foto-Fenton

AUTOR(ES)
FONTE

Química Nova

DATA DE PUBLICAÇÃO

2012

RESUMO

A continuous photochemical treatment system was developed for aiming the treatment of aqueous solutions containing relevant micro-pollutants (microcystin-LR, sulfamethoxazole and 17-b estradiol). The continuous photo-Fenton process provided high degradation efficiency. However, contact time between samples and the irradiated region is short relative to total treatment time, indicating that observed changes are predominantly due to the Fenton process. Higher degradation efficiency was observed in systems operated using two treatment cycles, the first involving a batch Fenton process and the second a continuous photo-Fenton treatment.