Comparison of E test with agar dilution for antimicrobial susceptibility testing of Neisseria gonorrhoeae.
AUTOR(ES)
Van Dyck, E
RESUMO
A collection of 150 Neisseria gonorrhoeae isolates from Africa, where various resistance mechanisms among N. gonorrhoeae isolates are common, was used to the compare E test (AB Biodisk, Solna, Sweden) with agar dilution susceptibility testing. MICs obtained by the E test agreed within 1 log2 concentration by the agar dilution method for 97.5, 97.3, 96.6, 94, and 84.7% of the tested isolates for penicillin, ciprofloxacin, chloramphenicol, tetracycline, and trimethoprim-sulfamethoxazole, respectively. No significant difference in susceptibility categorization was observed between either method. The E test is an attractive alternative to the agar dilution technique and is a more appropriate method for N. gonorrhoeae susceptibility testing in developing countries.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=264044Documentos Relacionados
- Comparison of broth microdilution and agar dilution for susceptibility testing of Neisseria gonorrhoeae.
- Comparison of microdilution and agar dilution procedures for testing antibiotic susceptibility of Neisseria gonorrhoeae.
- Comparison of E test and agar dilution for antimicrobial susceptibility testing of Stenotrophomonas (Xanthomonas) maltophilia.
- E Test versus Agar Dilution for Antimicrobial Susceptibility Testing of Viridans Group Streptococci
- Antimicrobial susceptibility testing of Haemophilus influenzae, Branhamella catarrhalis, and Neisseria gonorrhoeae.