Comparison of antibodies for rapid detection of cytomegalovirus.
AUTOR(ES)
Randazzo, D N
RESUMO
Antibodies were compared for use in the spin-amplified shell vial method for rapid cytomegalovirus detection. Commercial antibodies by Du Pont Co., Whittaker M.A. Bioproducts, Bartels Immunodiagnostic, Virostat, and Serono Diagnostics were compared at incubation times of 16 to 48 h on 22 patient specimens. Only the Du Pont antibody showed 100% sensitivity and specificity and no nonspecific reactions.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=266285Documentos Relacionados
- Comparison of four techniques for detection of antibodies to cytomegalovirus.
- Rapid dot enzyme immunoassay for the detection of antibodies to cytomegalovirus.
- Immunoperoxidase technique for detection of antibodies to human cytomegalovirus.
- Comparison of six methods for the detection of antibody to cytomegalovirus.
- Comparison of monoclonal antibodies for rapid detection of cytomegalovirus in spin-amplified plate cultures.