Comparison between indirect immunofluorescence and microneutralization for detection of antibodies to polioviruses.
AUTOR(ES)
Pettit, C
RESUMO
Indirect immunofluorescence and microneutralization methods for the detection of antibodies to poliovirus serotypes 1, 2, and 3 were compared. Of the 41 sera tested for poliovirus type 1 antibody, 40% were in complete agreement, 55% differed by one dilution, and 5% differed by two dilutions. For poliovirus type 2, 37 sera were tested; 56% completely agreed, and 44% differed by only one dilution. For poliovirus type 3, complete agreement occurred in 59% of 33 sera, while 41% differed by one dilution. No false-negative results were obtained. These findings suggest that indirect immunofluorescence for poliovirus types 1, 2, and 3 is as sensitive as the microneutralization method and could represent a less cumbersome alternative.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=269207Documentos Relacionados
- Comparison of indirect hemagglutination and indirect immunofluorescence tests with microneutralization tests for detection of type-specific Herpesvirus hominis antibody.
- Comparison of indirect immunofluorescence and Western blot for detection of anti-human immunodeficiency virus antibodies.
- Monoclonal antibodies of four different specificities for neutralization of type 1 polioviruses.
- Indirect immunofluorescence test for the detection of Aspergillus fumigatus antibodies
- Comparison of a semiautomated fluorescent immunoassay system and indirect immunofluorescence for detection of antinuclear antibodies in human serum.