CARACTERIZAÇÃO ELEMENTAR DA CASCA DE ARROZ E SUAS CINZAS POR MIP OES APÓS DECOMPOSIÇÃO ÁCIDA COM SISTEMA DE REFLUXO

AUTOR(ES)
FONTE

Quím. Nova

DATA DE PUBLICAÇÃO

2017-09

RESUMO

This paper describes the optimization of a sample preparation method using response surface methodology for Al, Cd, Cu, Fe, Mg, Mn, Mo, Na, Ni and Ti determinations in samples of rice husk and rice husk ash by MIP OES. Sample preparation was performed using a reflux system adapted to the digestion tubes. This system allowed the decomposition of the samples without the necessity of replacement of the acids during this step without any loss of volatile elements. The decompositions were performed with 3.6 mL of HNO3 and 1.4 mL of H2SO4 for 205 min in a digester block at 225 ºC. The detection limit for determination of respective analytes in both samples were satisfactory. The RSDs for the analytes were less than 10%. Moreover, the accuracy of the method can be verified by recovery tests, whose values ranged from 82 to 115% for husk samples and 82 to 120% for ashes. The proposed method was presented as a simple, safe and low cost procedure being suitable for sample preparation and subsequent determination of metals by MIP OES.