A system using disposable papier maché bedpans and urinals in hospital has advantages of ease of handling for the nurse and cleanliness for the patient. Disposal of the bedpans and their contents is by destruction and flushing to waste. Some bacteriological hazards of this process in the Haigh Sluicemaster and J.M.L. Clinimatic machines are assessed, particularly the dispersal of the contents in spray and aerosol during opening, closing, and running the machines. Various safety devices were tested and some deficiencies are discussed.