Bacterial antigen detection in body fluids: methods for rapid antigen concentration and reduction of nonspecific reactions.
AUTOR(ES)
Doskeland, S O
RESUMO
We sought procedures which would allow a rapid concentration in high yield of bacterial antigens from tissue fluids of patients and which could be applied also to protein-rich fluids like serum. Ethanol precipitation at a subzero temperature with albumin added as an antigen coprecipitant made it possible to achieve a more than 20-fold concentration of antigen in 15 min and a 200-fold concentration in 45 min. Heat-stable antigens could be concentrated from protein-rich fluids (like serum) after the sample had been deproteinized by boiling. Such heating (100 degrees C, 3 min) also liberated bacterial polysaccharides from antibody complexes and elminated the nonspecific interference of serum in enzyme-linked immunosorbent assay.
ACESSO AO ARTIGO
http://www.pubmedcentral.nih.gov/articlerender.fcgi?artid=273408Documentos Relacionados
- Phenylacetic acid in human body fluids: high correlation between plasma and cerebrospinal fluid concentration values.
- Rapid flow cytometric bacterial detection and determination of susceptibility to amikacin in body fluids and exudates.
- Inhibition of nonspecific streptococcal coagglutination reactions.
- Improved detection of bacterial antigens by latex agglutination after rapid extraction from body fluids.
- STUDY OF SOLUBILITY IN SUPERCRITICAL FLUIDS: THERMODYNAMIC CONCEPTS AND MEASUREMENT METHODS - A REVIEW