Analogue solution for electrical capacity of membrane covered square cylinders in square array at high concentration.

AUTOR(ES)
RESUMO

Analytical solutions of Laplace equations have given the electrical characteristics of membranes and interiors of spherical, ellipsoidal, and cylindrical cells in suspensions and tissues from impedance measurements, but the underlying assumptions may be invalid above 50% volume concentrations. However, resistance measurements on several nonconducting, close-packing forms in two and three dimensions closely predicted volume concentrations up to 100% by equations derived from Maxwell and Rayleigh. Calculations of membrane capacities of cells in suspensions and tissues from extensions of theory, as developed by Fricke and by Cole, have been useful but of unknown validity at high concentrations. A resistor analogue has been used to solve the finite difference approximation to the Laplace equation for the resistance and capacity of a square array of square cylindrical cells with surface capacity. An 11 x 11 array of resistors, simulating a quarter of the unit structure, was separated into intra- and extra-cellular regions by rows of capacitors corresponding to surface membrane areas from 3 x 3 to 11 x 11 or 7.5% to 100%. The extended Rayleigh equation predicted the cell concentrations and membrane capacities to within a few percent from boundary resistance and capacity measurements at low frequencies. This single example suggests that analytical solutions for other, similar two- and three-dimensional problems may be approximated up to near 100% concentrations and that there may be analytical justifications for such analogue solutions of Laplace equations.