Fia Flow Injection Analysis
Mostrando 1-12 de 68 artigos, teses e dissertações.
-
1. Synthesis, Characterization, Spectroelectrochemical, Photophysical and HSA-Binding Properties of Novel and Versatile meso-Tetra(4-pyridylvinylphenyl)porphyrins Coordinated to Ruthenium(II)-Polypyridyl Derivatives
The free-base meso-tetra(4-pyridylvinylphenyl)porphyrin (1a) and its zinc(II) complex were synthesized and then functionalized with [Ru(bpy)2Cl]+ units (2a and 2b) via conventional methods and evaluated in terms of photophysical, electrochemical and biological aspects. All porphyrins present moderate singlet oxygen production and fluorescence quantum yield,
J. Braz. Chem. Soc.. Publicado em: 2020-11
-
2. DETERMINAÇÃO RÁPIDA E SIMPLES DE CITRATO DE SILDENAFILA (VIAGRA® E GENÉRICOS) EMPREGANDO ELETRODO IMPRESSO DE CARBONO EM SISTEMAS FIA E BIA COM DETECÇÃO AMPEROMÉTRICA
This work presents two amperometric methods for Sildenafil Citrate (SC) determination in erectile dysfunction drugs (Viagra® and Generics), using Batch Injection Analysis (BIA) and Flow Injection Analysis (FIA) systems with a cell for Screen Printed Electrodes (SPE). In Britton- Robinson buffer solution (pH 2), the SC presented an irreversible anodic peak a
Quím. Nova. Publicado em: 2017-08
-
3. Flow-injection analysis with multiple-pulse amperometry for simultaneous determination of paracetamol and naproxen using a homemade flow cell for screen-printed electrodes
Este trabalho reporta a determinação simultânea de paracetamol e naproxeno usando a detecção amperométrica de múltiplos pulsos em um eletrodo impresso modificado com nanotubos de carbono de parades múltiplas (MWCNT-SPE) adaptado em uma célula de análise em fluxo (FIA) construída em laboratório. Uma sequência de dois pulsos de potencial (+0,30 e
J. Braz. Chem. Soc.. Publicado em: 2014-03
-
4. Electrochemical oxidation of chlorhexidine and its amperometric determination by flow-injection analysis
A oxidação electroquímica de clorexidina é investigada pela primeira vez e sua determinação amperométrica usando um sistema de análise por injeção em fluxo (FIA) é demonstrada. Um pico de oxidação bem definido foi observado próximo de 1,3 V em uma solução 0,1 mol L-1 de HClO4 em eletrodo de carbono vítreo. O mecanismo da oxidação eletroqu�
J. Braz. Chem. Soc.. Publicado em: 2014-03
-
5. Desenvolvimento de um sistema de análise por injeção em fluxo utilizando materiais alternativos de baixo custo para fins didáticos
This work describes a simple and inexpensive flow injection analysis system in which gravity force provides fluid propulsion while needles for insulin administration or metallic wires act as electrodes for amperometric detection. The proposed system was able to demonstrate the influence of several operational parameters on the transient signals. Moreover, th
Quím. Nova. Publicado em: 2014
-
6. Determinação de parâmetros cinéticos em fluxo com câmara de gradiente e deteção espectrofotométrica: aplicação à reação entre o violeta de cristal e o ião hidróxido
A didactic experiment is proposed aimed to extend the Flow Injection Analysis (FIA) based methodology to the area of physical chemistry/chemical reactors for undergraduate labs. Our prime objective was to describe the use of a gradient chamber for determination of the rate constant for the reaction between crystal violet and the hydroxide ion. The study was
Quím. Nova. Publicado em: 2013
-
7. Determinação de nimesulida por análise por injeção em fluxo com detecção amperométrica de múltiplos pulsos
A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms an
Quím. Nova. Publicado em: 2013
-
8. Determinação eletroquímica de glicerol em biodiesel por amperometria de múltiplos pulsos com eletrodo de ouro
Biodiesel is the fuel obtained from vegetable oils or animal fats that can partially or totally replace diesel oil. Besides being obtained from renewable sources, biodiesel is less polluting than diesel and biodegradable. One disadvantage of biodiesel is the byproduct of transesterification reaction of raw material, glycerol, which can cause damages to combu
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 22/06/2012
-
9. Preparação de hidróxidos mistos nanoestruturados de níquel/cobalto e desenvolvimento de sensores FIA amperométricos / Preparation of nanostructured nickel/cobalt mixed hydroxides and development of FIA amperometric sensors
Nesta tese foram desenvolvidos sensores amperométricos baseados em porfirinas supramoleculares e hidróxido de níquel nanoestruturado e estabilizado na fase alfa, bem como novos materiais baseados em hidróxidos mistos de níquel e cobalto nanoetruturados e estabilizados na fase alfa. Também, um analisador FIA amperométrico, foi desenvolvido em colabora�
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 21/03/2012
-
10. Determination of sildenafil citrate (Viagra®) in various pharmaceutical formulations by flow injection analysis with multiple pulse amperometric detection
O presente trabalho apresenta uma metodologia simples, rápida e de baixo custo para a determinação de citrato de sildenafila (SC) em formulações farmacêuticas de referência (Viagra®) e em produtos similares, genéricos e manipulados, por amperometria de múltiplos pulsos em sistema FIA (análise por injeção em fluxo). O método consiste na aplicaç
J. Braz. Chem. Soc.. Publicado em: 09/10/2012
-
11. Determination of phenol and o-cresol in soil extracts by flow injection analysis with spectrophotometric detection
Neste trabalho, propõe-se a determinação de fenol e o-cresol por análise por injeção em fluxo (FIA) com detecção espectrofotométrica, utilizando a reação com 4-aminoantipirina, a fim de quantificar essas espécies em extratos de solo. Após otimização das condições por planejamento fatorial, constatou-se uma maior frequência de amostragem em
Journal of the Brazilian Chemical Society. Publicado em: 2012-05
-
12. Short-term toxicity test: monitoring Klebsiella oxytoca bacterium respiration using a flow injection analysis/conductometric system
Neste estudo, foi desenvolvido um teste de toxicidade rápido, utilizando-se a bactéria Klebsiella oxytoca como organismo-teste. Ensaios com Escherichia coli foram usados como referência. A inibição do crescimento bacteriano foi avaliada por um sistema de análise por injeção em fluxo (FIA) com detecção condutométrica do CO2 produzido durante o proc
Journal of the Brazilian Chemical Society. Publicado em: 2012-03