Amperometric Biosensor
Mostrando 1-12 de 22 artigos, teses e dissertações.
-
1. On the Use of a TiO2 Sol-Gel for Horseradish Peroxidase Enzyme Immobilization for Development of an Amperometric Biosensor
The sol-gel technique has drawn considerable attention in the area of biomolecules immobilization by virtue of its intrinsic properties including chemical inertness, thermal stability, and good biocompatibility. The present work reports the development of a bio-sensing methodology which involves the immobilization of horseradish peroxidase enzyme (HRP) on pe
J. Braz. Chem. Soc.. Publicado em: 2021-06
-
2. Desenvolvimento de biossensor contendo polifenoloxidases de sementes de jatobá para análise ambiental / Developmento of biosensor containing polyphenoloxidase jatobá seed for environmental analysis
The polyphenoloxidase (PPO) is responsible for catalyzing the conversion of phenolic compounds to quinones in the presence of oxygen. This enzyme is widely used in biosensor production and selective evaluation of phenol content in industrial effluents. In this work a biosensor modified with enzyme extract containing polyphenoloxidase from Hymenaea stigonocar
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 08/09/2011
-
3. Synthesis, characterization and application of poly(3- hydroxyphenylacetic acid) in the development of a biosensor for detection of cardiac marker / Síntese, caracterização e aplicação do poli (ácido 3-Hidroxifenilacético) no desenvolvimento de biossensor para detecção de marcador cardíaco
Neste trabalho foram realizados estudos de caracterização de um novo material, o poli(ácido 3-hidroxifenilacético) e sua aplicação para construção de um imunossensor amperométrico para detecção do Infarto Agudo do Miocárdio (IAM). Inicialmente, foi realizada a eletropolimerização do ácido 3-hidroxifenilacético em três pHs diferentes (0,0; 6,
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 25/02/2011
-
4. Desenvolvimento de dispositivos eletroquímicos descartáveis para análises rápidas / Development of disposable electrochemical devices for rapid analysis
This paper presents the efforts to the construction and characterization of electrochemical transducers on polyester and paper, and also demonstrates the use of these disposable electrochemical cells in the development of a biosensor for rapid analysis of salicylate in blood as well as the creation of a separation device associated electrochemical detection
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 20/08/2010
-
5. Low potential stable glucose detection at dendrimers modified polyaniline nanotubes
The utilization of nanostructured materials for development of biosensors is a growing field in medical diagnostics. In this work a glucose biosensor based on bioactive polyglycerol (PGLD) and chitosan dendrimers (CHD) was developed. PGLD and CHD were bioconjugated with the enzyme glucose oxidase (GOx) to obtain dendrimers with glucose sensing properties. Po
Materials Research. Publicado em: 2010-03
-
6. DESENVOLVIMENTO DE MÉTODOS EMPREGANDO SPME-GC/MS E BIOSSENSORES AMPEROMÉTRICOS PARA ANÁLISE DO INSETICIDA PARATION METÍLICO EM AMOSTRAS DE ARROZ IN NATURA / DEVELOPMENT AND METHODS EMPLOYING SPME-GC/MS AMPEROMETRIC BIOSENSOR FOR METHYL PARATHION ANALYSIS OF PESTICIDE IN SAMPLES OF RICE IN NATURA
Os inseticidas organofosforados, em especial aqueles à base do princípio ativo paration metílico, têm sido extensivamente usados na proteção de cultivos de arroz no Estado do Maranhão. Neste trabalho, foi otimizado um método cromatográfico para determinação do inseticida paration metílico usando microextração em fase sólida em ambiente confina
Publicado em: 2010
-
7. Eletrodos modificados com agentes biológicos por diferentes procedimentos de imobilização
A carbon paste electrode modified with enzyme laccase productNovozym 51.003 has been proposed in this manuscript. This enzyme catalyzesthe oxidation of different types of phenols compounds, and lignin aminefunctional groups engaged. This enzyme has been among the most applied inthe construction of biosensor amperometric Electrical. The effect of laccaseamoun
IBICT - Instituto Brasileiro de Informação em Ciência e Tecnologia. Publicado em: 17/11/2009
-
8. Electrosynthesis and characterizations of polypyrrole-2-carboxylic acid for application as amperometric biosensor constructed in microelectrodes / Eletrossíntese e caracterização de filmes de polipirrol-2-ácido carboxílico para uso em biossensores amperométricos construídos em eletrodos miniaturizados
In this work, we present the electrochemical synthesis of a new conducting polymer derived of polypyrrole (PPI) functionalized by carboxylic group, the polypyrrole-2-carboxylic acid, and its application as amperometric transducer in biosensor by use of polyphenol oxidase (PFO). All the steps of syntheses and characterization of the polymer film in microelect
Publicado em: 2009
-
9. Optimization of an amperometric biosensor for the detection of hepatitis C virus using fractional factorial designs
O planejamento fatorial fracionário e com ponto central foram aplicados no desenvolvimento de um biossensor amperométrico para determinação do vírus da hepatite C. As biomoléculas foram imobilizadas por adsorção em eletrodos de grafite modificados com filme sol-gel preparado com matriz híbrida siloxano-poli(propileno-óxido). Diversos parâmetros fo
Journal of the Brazilian Chemical Society. Publicado em: 2008
-
10. Desenvolvimento de um biossensor amperomÃtrico de DNA para detecÃÃo do PapilomavÃrus humano
The cervical cancer has been a serious problem in Brazil and in the world wuith about 18.680 infected woman annually. The Human Papillomavirus (HPV) has been biologically associated with the development of cervical lesions, due to its capacity to infect epithelial cells and progress to cervical uterine cancer. The late screening may unviable the treatment, l
Publicado em: 2008
-
11. Fabrication of a biosensor for determination of lactate in food and blood samples / Desenvolvimento de um sensor para análise de lactato em amostras alimentares e biológicas
Results on the investigation of the electrochemical behavior of lactate and hydrogen peroxide at various electrodic surfaces at different pHs using cyclic voltammetry are presented. Experiments were also carried out with platinum and glassy carbon electrodes modified with hexacyanoferrate films. The advantage of using CTAB in the electrodeposition step of Pr
Publicado em: 2007
-
12. Synthesis and characterization of copper hexacyanoferate nanoparticles and its application in Glucose Biosensor and electrochromics electrodes / Síntese e caracterização de nanopartículas de hexacianoferrato de cobre e sua aplicação em biossensores de glicose e eletrodos eletrocrômicos
In this work, the sonochemical synthesis and the characterization of copper hexacyanoferrate nanoparticles for producing ultra thin films with controlled thickness is reported. Due to its nanometric structure and the excess of superficial negative charges, the proposed immobilization methods were the electrostatic deposition layer by layer (LBL), using the P
Publicado em: 2007